汇峰国际城模板施工方案立柱截面面积A(mm2)
立柱截面回转半径i(mm)
立柱截面抵抗矩W(cm3)
抗压强度设计值[f](N/mm2)
实用装饰工程施工组织设计顶部立杆段:l01=kμ1(hd+2a)=1×1.386×(1500+2×200)=2633.4mm
非顶部立杆段:l02=kμ2h=1×1.755×1800=3159mm
λ=l0/i=3159/15.9=198.68≤[λ]=210
顶部立杆段:l01=kμ1(hd+2a)=1.155×1.386×(1500+2×200)=3041.577mm
λ1=l01/i=3041.577/15.9=191.294,查表得,φ1=0.197
Mw=0.92×1.4ωklah2/10=0.92×1.4×0.18×0.9×1.82/10=0.06kN·m
Nw=0.9[1.2ΣNGik+0.9×1.4Σ(NQik+Mw/lb)]=0.9×[1.2×(0.5+(24+1.1)×0.15)+0.9×1.4×1]×0.9×0.9+0.92×1.4×0.06/0.9=4.72kN
f=Nw/(φA)+Mw/W=4724.56/(0.2×424)+0.06×106/4490=69.82N/mm2≤[f]=205N/mm2
非顶部立杆段:l02=kμ2h=1.155×1.755×1800=3648.645mm
λ2=l02/i=3648.645/15.9=229.475,查表得,φ2=0.139
非顶部立杆段:l02=kμ2h=1.155×1.755×1800=3648.645mm
λ2=l02/i=3648.645/15.9=229.475,查表得,φ2=0.139
Mw=0.92×1.4ωklah2/10=0.92×1.4×0.18×0.9×1.82/10=0.06kN·m
Nw=0.9[1.2ΣNGik+0.9×1.4Σ(NQik+Mw/lb)]=0.9×[1.2×(0.75+(24+1.1)×0.15)+0.9×1.4×1]×0.9×0.9+0.92×1.4×0.06/0.9=4.94kN
f=Nw/(φA)+Mw/W=4943.26/(0.14×424)+0.06×106/4490=97.13N/mm2≤[f]=205N/mm2
扣件抗滑移折减系数kc
按上节计算可知,扣件受力N=4.72kN≤Rc=kc×12=1×12=12kN
地基承载力设计值fak(kPa)
立柱垫木地基土承载力折减系数mf
垫板底面面积A(m2)
立柱底垫板的底面平均压力p=N/(mfA)=4.94/(1×0.1)=49.43kPa≤fak=70kPa
梁模板(扣件式)计算书
新浇混凝土梁计算跨度(m)
混凝土梁截面尺寸(mm×mm)
新浇混凝土结构层高(m)
模板及其支架自重标准值G1k(kN/m2)
新浇筑混凝土自重标准值G2k(kN/m3)
钢筋自重标准值G3k(kN/m3)
施工人员及设备荷载标准值Q1k
当计算支架立柱及其他支承结构构件时(kN/m2)
振捣混凝土时产生的荷载标准值Q2k(kN/m2)
风荷载标准值ωk(kN/m2)
基本风压ω0(kN/m2)
梁两侧有板,梁板立柱共用(A)
梁跨度方向立柱间距la(mm)
梁两侧立柱间距lb(mm)
新浇混凝土楼板立柱间距l'a(mm)、l'b(mm)
混凝土梁居梁两侧立柱中的位置
梁左侧立柱距梁中心线距离(mm)
梁底增加立柱依次距梁左侧立柱距离(mm)
梁底支撑小梁最大悬挑长度(mm)
面板抗弯强度设计值[f](N/mm2)
面板弹性模量E(N/mm2)
取单位宽度1000mm,按三等跨连续梁计算,计算简图如下:
W=bh2/6=1000×18×18/6=54000mm3,I=bh3/12=1000×18×18×18/12=486000mm4
q1=0.9max[1.2(G1k+(G2k+G3k)×h)+1.4Q2k,1.35(G1k+(G2k+G3k)×h)+1.4×0.7Q2k]×b=0.9max[1.2×(0.1+(24+1.5)×0.8)+1.4×2,1.35×(0.1+(24+1.5)×0.8)+1.4×0.7×2]×1=26.67kN/m
q1静=0.9×1.35×[G1k+(G2k+G3k)×h]×b=0.9×1.35×[0.1+(24+1.5)×0.8]×1=24.91kN/m
q1活=0.9×1.4×0.7×Q2k×b=0.9×1.4×0.7×2×1=1.76kN/m
q2=(G1k+(G2k+G3k)×h)×b=[0.1+(24+1.5)×0.8]×1=20.5kN/m
Mmax=0.1q1静L2+0.117q1活L2=0.1×24.91×0.12+0.117×1.76×0.12=0.03kN·m
σ=Mmax/W=0.03×106/54000=0.5N/mm2≤[f]=15N/mm2
νmax=0.677qL4/(100EI)=0.677×20.5×1004/(100×10000×486000)=0.003mm≤[ν]=l/400=100/400=0.25mm
设计值(承载能力极限状态)
R1=R4=0.4q1静l+0.45q1活l=0.4×24.91×0.1+0.45×1.76×0.1=1.08kN
R2=R3=1.1q1静l+1.2q1活l=1.1×24.91×0.1+1.2×1.76×0.1=2.95kN
标准值(正常使用极限状态)
R1'=R4'=0.4q2l=0.4×20.5×0.1=0.82kN
R2'=R3'=1.1q2l=1.1×20.5×0.1=2.26kN
小梁抗弯强度设计值[f](N/mm2)
小梁抗剪强度设计值[τ](N/mm2)
小梁弹性模量E(N/mm2)
小梁截面抵抗矩W(cm3)
小梁截面惯性矩I(cm4)
为简化计算,按四等跨连续梁和悬臂梁分别计算,如下图:
Mmax=max[0.107q1l12,0.5q1l22]=max[0.107×2.98×0.92,0.5×2.98×0.22]=0.26kN·m
σ=Mmax/W=0.26×106/83330=3.1N/mm2≤[f]=15.44N/mm2
Vmax=max[0.607q1l1,q1l2]=max[0.607×2.98×0.9,2.98×0.2]=1.626kN
τmax=3Vmax/(2bh0)=3×1.626×1000/(2×50×100)=0.49N/mm2≤[τ]=1.78N/mm2
ν1=0.632q2l14/(100EI)=0.632×2.28×9004/(100×9350×4166700)=0.24mm≤[ν]=l/400=900/400=2.25mm
ν2=q2l24/(8EI)=2.28×2004/(8×9350×4166700)=0.01mm≤[ν]=l/400=200/400=0.5mm
梁头处(即梁底支撑小梁悬挑段根部)
Rmax=max[1.143q1l1,0.393q1l1+q1l2]=max[1.143×2.98×0.9,0.393×2.98×0.9+2.98×0.2]=3.06kN
同理可得,梁底支撑小梁所受最大支座反力依次为R1=R4=2.69kN,R2=R3=3.06kN
R'max=max[1.143q2l1,0.393q2l1+q2l2]=max[1.143×2.28×0.9,0.393×2.28×0.9+2.28×0.2]=2.34kN
同理可得,梁底支撑小梁所受最大支座反力依次为R'1=R'4=2.43kN,R'2=R'3=2.34kN
主梁弹性模量E(N/mm2)
主梁抗弯强度设计值[f](N/mm2)
主梁抗剪强度设计值[τ](N/mm2)
主梁截面惯性矩I(cm4)
主梁截面抵抗矩W(cm3)
主梁自重忽略不计,计算简图如下:
主梁弯矩图(kN·m)
σ=Mmax/W=0.139×106/4490=30.89N/mm2≤[f]=205N/mm2
Vmax=2.406kN
τmax=2Vmax/A=2×2.406×1000/424=11.35N/mm2≤[τ]=125N/mm2
νmax=0.06mm≤[ν]=l/400=450/400=1.12mm
R=max[R1,R4]=0.28kN≤8kN
单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!
同理可知,左侧立柱扣件受力R=0.28kN≤8kN
单扣件在扭矩达到40~65N·m且无质量缺陷的情况下,单扣件能满足要求!
立柱截面面积A(mm2)
立柱截面抵抗矩W(cm3)
抗压强度设计值f(N/mm2)
λ=h/i=1800/15.9=113.21≤[λ]=150
Mw=0.92×1.4×ωk×la×h2/10=0.92×1.4×0.22×0.9×1.82/10=0.07kN·m
q1=0.9×[1.2×(0.1+(24+1.5)×0.8)+0.9×1.4×2]×1=24.41kN/m
同上四~六计算过程,可得:
R1=0.27kN,R2=5.14kN,R3=5.14kN,R4=0.27kN
f=N/(φA)+Mw/W=5281.81/(0.5×424)+0.07×106/4490=41.32N/mm2≤[f]=205N/mm2
八、梁底立柱扣件抗滑移验算
JGJ/T 479-2019 低温辐射自限温电热片供暖系统应用技术标准(完整清晰正版).pdf扣件抗滑移折减系数kc
由"主梁验算"一节计算可知扣件最大受力N=max[R2,R3]×1=5.47kN≤Rc=kc×12=1×12=12kN
地基承载力设计值fak(kPa)
【河北图集】J17J168:村镇住宅建筑设计构造立柱垫木地基土承载力折减系数mf
垫板底面面积A(m2)
立柱底垫板的底面平均压力p=N/(mfA)=5.28/(1×0.15)=35.21kPa≤fak=140kPa