T梁张拉计算及施工方案

p—预应力筋张拉端的张拉力,N;

θ—从张拉端至计算截面曲线孔道部分切线的夹角之和,rad;

R—孔道每米局部偏差对摩擦的影响系数,0.0015;

μ—预应力筋与孔道避的摩擦系数湘2015G101-4 装配式结构住宅--17层混凝土结构城镇住宅(<54m)㈣,0.1;

(一)35mT梁中主梁

预应力筋截面面积Ay=140*7=980mm2

锚下控制应力σk=0.72Ryb=0.72*1860=1339.2MPa

起始端头张拉力p1=σk*Ay=1339.2*980=1312.416KN

由图纸说明:θ=4.46°*3.14/180°=0.0778rad

L直1=11.9239*2=23.8478m

μ=0.1,R=0.0015,

P=P×=1124.928*

      kL+μθ0.0015*3.1106+0.1*0.0778

=1304.282KN

△L==1304.282*3.1106/(980*1.96*105)

      Ay×Eg

L直1=P2×L/Ay×E=1296.149*23.8478/980/1.96*105=16.1cm

L直2=P1×L/Ay×E=1312.416*2.3056/980/1.96*105=1.58cm

L=16.1+2.11*2+1.58*2=23.48cm

预应力筋截面面积Ay=140*6=980mm2

锚下控制应力σk=0.72Ryb=0.72*1860=1339.2MPa

起始端头张拉力p1=σk*Ay=1339.2*980=1312.416KN

由图纸说明:θ=5.86°*3.14/180°=0.1022rad

L直1=9.4341*2=18.8682m

μ=0.1,R=0.0015,

P=P×=1124.928*

      kL+μθ0.0015*4.0883+0.1*0.1022

=1301.742KN

△L==1301.742*4.0883/(980*1.96*105)

      Ay×Eg

L直1=P2×L/Ay×E=1291.068*18.8682/980/1.96*105=12.69cm

L直2=P1×L/Ay×E=1312.416*3.83475/980/1.96*105=2.62cm

L=12.69+2.77*2+2.62*2=23.47cm

预应力筋截面面积Ay=140*6=980mm2

锚下控制应力σk=0.72Ryb=0.72*1860=1339.2MPa

起始端头张拉力p1=σk*Ay=1339.2*980=1312.416KN

由图纸说明:θ=6.54°*3.14/180°=0.1141rad

L直1=7.1945*2=14.389m

μ=0.1,R=0.0015,

P=P×=1124.928*

      kL+μθ0.0015*4.5661+0.1*0.1141

=1300.508KN

△L==1300.508*4.5661/(980*1.96*105)

      Ay×Eg

L直1=P2×L/Ay×E=1288.599*14.389/980/1.96*105=9.66cm

L直2=P1×L/Ay×E=1312.416*5.61585/980/1.96*105=3.84cm

L=9.66+3.09*2+3.84*2=23.52cm

预应力筋截面面积Ay=140*6=980mm2

锚下控制应力σk=0.72Ryb=0.72*1860=1339.2MPa

起始端头张拉力p1=σk*Ay=1339.2*980=1312.416KN

由图纸说明:θ=6.37°*3.14/180°=0.1111rad

L直1=5.2534*2=10.5068m

μ=0.1,R=0.0015,

P=P×=1124.928*

      kL+μθ0.0015*4.4486+0.1*0.1111

=1300.814KN

△L==1300.814*4.4486/(980*1.96*105)

      Ay×Eg

L直1=P2×L/Ay×E=1289.212*10.5068/980/1.96*105=7.05cm

L直2=P1×L/Ay×E=1312.416*7.68465/980/1.96*105=5.25cm

L=7.05+3.01*2+5.26*2=23.59cm

预应力筋截面面积Ay=140*6=980mm2

锚下控制应力σk=0.72Ryb=0.72*1860=1339.2MPa

起始端头张拉力p1=σk*Ay=1339.2*980=1312.416KN

由图纸说明:θ=6.74°*3.14/180°=0.1176rad

L直1=3.1253*2=6.2506m

μ=0.1,R=0.0015,

P=P×=1124.928*

      kL+μθ0.0015*4.7039+0.1*0.1176

=1300.148KN

△L==1300.148*4.7039/(980*1.96*105)

      Ay×Eg

L直1=P2×L/Ay×E=1287.879*6.2506/980/1.96*105=4.19cm

L直2=P1×L/Ay×E=1312.416*9.5778/980/1.96*105=6.55cm

L=4.19+3.18*2+6.55*2=23.65cm

(二)35mT梁边主梁

预应力筋截面面积Ay=140*8=1120mm2

锚下控制应力σk=0.72Ryb=0.72*1860=1339.2MPa

起始端头张拉力p1=σk*Ay=1339.2*1120=1499.904KN

由图纸说明:θ=2.23°*3.14/180°=0.0389rad

L直1=12.7011*2=25.4022m

μ=0.1,R=0.0015,

P=P×=1124.928*

      kL+μθ0.0015*1.5577+0.1*0.0389

△L==1495.24*1.5577/(1120*1.96*105)

      Ay×Eg

L直1=P2×L/Ay×E=1490.58*25.4022/1120/1.96*105=17.25cm

L直2=P1×L/Ay×E=1499.904*3.0739/1120/1.96*105=2.1cm

L=17.26+1.06*2+2.1*2=23.58cm

预应力筋截面面积Ay=140*8=1120mm2

锚下控制应力σk=0.72Ryb=0.72*1860=1339.2MPa

起始端头张拉力p1=σk*Ay=1339.2*1120=1499.904KN

由图纸说明:θ=4.4°*3.14/180°=0.077rad

L直1=9.9438*2=19.8876m

μ=0.1,R=0.0015,

P=P×=1124.928*

      kL+μθ0.0015*3.0709+0.1*0.077

=1490.731KN

△L==1490.731*3.0709/(1120*1.96*105)

      Ay×Eg

L直1=P2×L/Ay×E=1481.558*19.8876/1120/1.96*105=13.43cm

L直2=P1×L/Ay×E=1499.904*4.33105/1120/1.96*105=2.96cm

L=13.42+2.09*2+2.96*2=23.52cm

预应力筋截面面积Ay=140*8=1120mm2

锚下控制应力σk=0.72Ryb=0.72*1860=1339.2MPa

起始端头张拉力p1=σk*Ay=1339.2*1120=1499.904KN

由图纸说明:θ=5.46°*3.14/180°=0.0952rad

L直1=7.5735*2=15.147m

μ=0.1,R=0.0015,

P=P×=1124.928*

      kL+μθ0.0015*3.8101+0.1*0.0952

=1488.533KN

△L==1488.533*3.8101/(1120*1.96*105)

      Ay×Eg

L直1=P2×L/Ay×E=1477.161*15.147/1120/1.96*105=10.20cm

L直2=P1×L/Ay×E=1499.904*5.97925/1120/1.96*105=4.09cm

L=10.20+2.58*2+4.09*2=23.54cm

预应力筋截面面积Ay=140*8=1120mm2

锚下控制应力σk=0.72Ryb=0.72*1860=1339.2MPa

起始端头张拉力p1=σk*Ay=1339.2*1120=1499.904KN

由图纸说明:θ=5.51°*3.14/180°=0.0961rad

L直1=5.5555*2=11.111m

μ=0.1,R=0.0015,

P=P×=1124.928*

      kL+μθ0.0015*3.846+0.1*0.0961

=1488.428KN

△L==1488.428*3.846/(1120*1.96*105)

      Ay×Eg

L直1=P2×L/Ay×E=1476.952*11.111/1120/1.96*105=7.47cm

L直2=P1×L/Ay×E=1499.904*7.97125/1120/1.96*105=5.45cm

L=7.47+2.61*2+5.45*2=23.59cm

预应力筋截面面积Ay=140*8=1120mm2

锚下控制应力σk=0.72Ryb=0.72*1860=1339.2MPa

起始端头张拉力p1=σk*Ay=1339.2*1120=1499.904KN

由图纸说明:θ=6.02°*3.14/180°=0.105rad

L直1=3.3761*2=6.7522m

μ=0.1,R=0.0015,

P=P×=1124.928*

      kL+μθ0.0015*4.2039+0.1*0.105

△L==1487.37*4.2039/(1120*1.96*105)

      Ay×Eg

L直1=P2×L/Ay×E=1474.835*6.7522/1120/1.96*105=4.53cm

L直2=P1×L/Ay×E=1499.904*9.81185/1120/1.96*105=6.71cm

L=4.53+2.85*2+6.71*2=23.65cm

预应力筋截面面积Ay=140*8=1120mm2

锚下控制应力σk=0.72Ryb=0.72*1860=1339.2MPa

起始端头张拉力p1=σk*Ay=1339.2*1120=1499.904KN

由图纸说明:θ=6.39°*3.14/180°=0.111rad

L直1=1.2487*2=2.4974m

μ=0.1,R=0.0015,

P=P×=1124.928*

      kL+μθ0.0015*4.458+0.1*0.111

=1486.609KN

△L==1486.609*4.458/(1120*1.96*105)

      Ay×Eg

L直1=P2×L/Ay×E=1473.313*2.4974/1120/1.96*105=1.68cm

L直2=P1×L/Ay×E=1499.904*11.70515/1120/1.96*105=8.00cm

L=1.68+3.02*2+8.00*2=23.72cm

千斤顶工作长度的伸长量计算:

ΔL=PL/AyEy=σk*Ay*L/AyEy=σk*L/Ey=1339.2*0.58/1.96*105

1、预应力筋张拉完毕后尽早压浆;

2、孔道压浆宜采用水泥浆,水泥浆强28天抗压强度不小于30Mpa(用70.7mm立方体测试),水泥浆的技术条件应符合下列规定:

①、水泥宜采用硅酸盐水泥和普通水泥,水泥标号不得低于P.O42.5;

②、水灰比宜为0.3~0.35,可掺入适量减水剂以增加流动性;

③、水泥浆的泌水率最大不得超过3%,拌和后3小时泌水率宜控制在2%,浆体流动度≤30S,泌水应在24h内重新全部被浆吸回;

④、流动性在流动性测定仪上进行试验,水泥浆自仪器内流出的时间不超过6秒;

⑤、膨胀率水泥浆中(通过试验)可掺入适当砼膨胀剂,膨胀剂的掺入量参照其与水泥用量的比例规定及试验所得结果,水泥浆掺入膨胀剂后的自由膨胀应小于10%;

⑥、收缩率不大于2%;

3、水泥浆的拌制,先下水再下水泥,拌和时间不得少于1min,灰浆过筛后存放在储浆桶内,水泥浆自调制到压入管道的时间间隔不得超过40分钟,水泥浆在灰浆桶仍不停地低速搅拌。

4、压浆前用高压水对孔道进行冲洗以排除孔内杂物K31 158圆管涵施工方案,如有积水应用吹风排除,但要保持孔内润湿。

6、真空稳定后,保证真空泵运行的同时,往压浆端的水泥浆入口压浆。一条波纹管的压浆必须连续进行。

7、当透明胶管有水泥浆流出后,关闭真空阀,打开排浆阀继续压浆。压浆至浆体连续喷出且稠度与入浆体相当时,关闭排浆阀至压力为0.7Mpa左右,持压2分钟后关闭排浆阀。

8、持压过程中应从低到高依次打开埋设于波纹管各峰顶排气管,排出残余空气及泌水山东某小区绿化工程施工组织设计,保证浆体饱满。待浆体失去流动性后可拆除压浆阀及排气阀。

9、压浆过程中及压浆后48h内,结构砼的湿度不得低于5度,否则应采取保护措施,当气温高于35度时,压浆宜在夜间进行。

10、孔道压浆时填好施工记录。