标准规范下载简介
DBJ∕T 15-211-2021 回弹法检测泵送混凝土抗压强度技术规程.pdf式中:f°一一试件抗压强度换算值; R一一试件回弹代表值; 3计算各函数关系式的平均相对误差()和相 对标准差(e),平均相对误差()不应大于土14.0% 相对标准差(e.)不应大于17.0%。
A.0.6选取相对标准差和平均相对误差较小且理论
Q/GDW 11694-2017标准下载A.0.6选取相对标准差和平均相对误差较小且理论 分析比较合理的函数关系式作为本地区测强曲线公 式。
根据选定的测强曲线公式,由测区回弹代表值 和碳化深度值计算出测区混凝土强度换算值,列出 则区混凝土强度换算表,供速查使用。由第个测区 的回弹代表值R和碳化深度值αm按表B可直接查
表B测区混凝土强度换算表
续表B测区测区混凝土强度换算值f(MPa)回弹测区平均碳化深度值dm(mm)代表0.00.51.01.52.02.53.03.54.04.55.05.5≥6.0值R23.116.716.315.815.415.023.216.816.416.015.515.123.317.016.516.115.715.323.417.116.716.215.815.415.023.517.316.816.415.915.515.123.617.416.916.516.115.615.223.717.517.116.616.215.815.423.817.717.216.816.315.915.515.123.917.817.416.916.516.015.615.224.018.017.517.016.616.215.715.324.118.117.617.216.716.315.915.415.024.218.317.817.316.916.416.015.615.224.318.417.917.517.016.516.115.715.324.418.618.117.617.116.716.215.815.415.024.518.718.217.717.316.816.415.915.515.124.618.918.417.917.416.916.516.115.615.224.719.018.518.017.517.116.616.215.815.324.819.118.618.217.717.216.816.315.915.515.124.919.318.818.317.817.316.916.416.015.615.225.019.418.918.417.917.517.016.616.115.715.329
续表B测区测区混凝土强度换算值fa(MPa)回弹测区平均碳化深度值dm(mm)代表0.00.51.01.52.02.53.03.54.04.55.05.5值R6.025.119.619.118.618.117.617.116.716.315.815.415.025.219.719.218.718.217.717.316.816.415.915.515.125.319.919.418.918.417.917.417.016.516.115.615.225.420.119.519.018.518.017.517.116.616.215.815.425.520.219.719.218.618.217.717.216.816.315.915.515.125.620.419.819.318.818.317.817.316.916.416.015.615.225.720.520.019.418.918.417.917.517.016.616.115.715.325.820.720.119.619.118.618.117.617.116.716.215.815.415.025.920.820.319.719.218.718.217.717.316.816.415.915.515.126.021.020.419.919.418.818.417.917.416.916.516.115.615.226.121.120.620.019.519.018.518.017.517.116.616.215.715.326.221.320.720.219.619.118.618.117.717.216.716.315.915.426.321.420.920.319.819.318.818.317.817.316.916.416.015.626.421.621.020.519.919.418.918.417.917.417.016.516.115.726.521.821.220.620.119.619.018.518.017.617.116.716.215.826.621.921.320.820.219.719.218.718.217.717.216.816.315.926.722.121.520.920.419.819.318.818.317.817.416.916.516.026.822.221.621.120.520.019.518.918.418.017.517.016.616.126.922.421.821.220.720.119.619.118.618.117.617.116.716.327.022.622.021.420.820.319.719.218.718.217.717.316.816.430
续表B测区测区混凝土强度换算值fa(MPa)回弹测区平均碳化深度值dm(mm)代表0.00.51.01.52.02.53.03.54.04.55.05.5值R6.027.122.722.121.521.020.419.919.418.818.317.917.416.916.527.222.922.321.721.120.620.019.519.018.518.017.517.116.627.323.022.421.821.320.720.219.619.118.618.117.617.216.727.423.222.622.021.420.820.319.819.218.718.217.817.316.827.523.422.722.121.621.020.419.919.418.918.417.917.417.027.623.522.922.321.721.120.620.019.519.018.518.017.517.127.723.723.122.521.921.320.720.219.719.118.618.117.717.227.823.923.222.622.021.420.920.319.819.318.818.317.817.327.924.023.422.822.221.621.020.519.919.418.918.417.917.428.024.223.622.922.321.721.220.620.119.519.018.518.017.628.124.423.723.122.521.921.320.720.219.719.218.618.217.728.224.523.923.222.622.021.520.920.319.819.318.818.317.828.324.724.023.422.822.221.621.020.519.919.418.918.417.928.424.924.223.622.922.321.821.220.620.119.519.018.518.028.525.024.423.723.122.521.921.320.820.219.719.218.718.228.625.224.523.923.322.622.021.520.920.319.819.318.818.328.725.424.724.023.422.822.221.621.020.519.919.418.918.428.825.524.924.223.622.922.321.821.220.620.119.619.018.528.925.725.024.423.723.122.521.921.320.820.219.719.218.729.025.925.224.523.923.322.622.021.520.920.319.819.318.831
续表B测区测区混凝土强度换算值fa(MPa)回弹测区平均碳化深度值dm(mm)代表0.00.51.01.52.02.53.03.54.04.55.05.5值R6.029.126.125.424.724.023.422.822.221.621.020.519.919.418.929.226.225.524.924.223.622.922.321.821.220.620.119.519.029.326.425.725.024.423.723.122.521.921.320.820.219.719.229.426.625.925.224.523.923.222.622.021.520.920.319.819.329.526.726.025.424.724.023.422.822.221.621.020.519.919.429.626.926.225.524.824.223.622.922.321.721.220.620.119.529.727.126.425.725.024.323.723.122.521.921.320.720.219.729.827.326.625.925.224.523.923.222.622.021.420.920.319.829.927.426.726.025.324.724.023.422.822.221.621.020.519.930.027.626.926.225.524.824.223.522.922.321.721.120.620.030.127.827.126.425.725.024.323.723.122.521.921.320.720.230.228.027.226.525.825.124.523.823.222.622.021.420.920.330.328.227.426.726.025.324.624.023.422.722.121.621.020.430.428.327.626.926.225.524.824.123.522.922.321.721.120.630.528.527.827.026.325.625.024.323.723.022.421.821.320.730.628.727.927.226.525.825.124.423.823.222.622.021.420.830.728.928.127.426.726.025.324.624.023.322.722.121.521.030.829.128.327.526.826.125.424.824.123.522.922.221.721.130.929.228.527.727.026.325.624.924.323.623.022.421.821.231.029.428.627.927.226.425.725.124.423.823.122.521.921.432
续表B测区测区混凝土强度换算值fa(MPa)回弹测区平均碳化深度值dm(mm)代表0.00.51.01.52.02.53.03.54.04.55.05.57值R6.031.129.628.828.127.326.625.925.224.623.923.322.722.121.531.229.829.028.227.526.826.125.424.724.123.422.822.221.631.330.029.228.427.726.926.225.524.924.223.622.922.321.831.430.229.428.627.827.126.425.725.024.423.723.122.521.931.530.329.528.828.027.326.625.925.224.523.923.222.622.031.630.529.728.928.227.426.726.025.324.724.023.422.822.231.730.729.929.128.427.626.926.225.524.824.223.522.922.331.830.930.129.328.527.827.026.325.625.024.323.723.022.431.931.130.329.528.727.927.226.525.825.124.423.823.222.632.031.330.529.728.928.127.426.625.925.324.623.923.322.732.131.530.629.829.028.327.526.826.125.424.724.123.522.832.231.730.830.029.228.427.727.026.325.624.924.223.623.032.331.831.030.229.428.627.927.126.425.725.024.423.723.132.432.031.230.429.628.828.027.326.625.925.224.523.923.332.532.231.430.529.729.028.227.526.726.025.324.724.023.432.632.431.630.729.929.128.427.626.926.225.524.824.223.532.732.631.730.930.129.328.527.827.026.325.625.024.323.732.832.831.931.130.329.528.727.927.226.525.825.124.523.832.933.032.131.330.529.728.928.127.426.625.925.324.623.933.033.232.331.530.629.829.028.327.526.826.125.424.724.133
续表B测区测区混凝土强度换算值fa(MPa)回弹测区平均碳化深度值dm(mm)代表0.00.51.01.52.02.53.03.54.04.55.05.5值R6.033.133.432.531.630.830.029.228.427.727.026.225.624.924.233.233.632.731.831.030.229.428.627.827.126.425.725.024.433.333.832.932.031.230.329.528.828.027.326.625.925.224.533.434.033.132.231.430.529.728.928.227.426.726.025.324.733.534.233.332.431.530.729.929.128.327.626.926.225.524.833.634.433.532.631.730.930.129.328.527.727.026.325.624.933.734.633.632.831.931.130.229.428.727.927.226.525.825.133.834.833.832.932.131.230.429.628.828.127.326.625.925.233.935.034.033.132.331.430.629.829.028.227.526.826.125.434.035.134.233.332.431.630.829.929.228.427.626.926.225.534.135.334.433.532.631.830.930.129.328.527.827.126.325.734.235.534.633.732.831.931.130.329.528.728.027.226.525.834.335.734.833.933.032.131.330.529.728.928.127.426.625.934.436.035.034.133.232.331.530.629.829.028.327.526.826.134.536.235.234.333.432.531.630.830.029.228.427.726.926.234.636.435.434.533.632.731.831.030.229.428.627.827.126.434.736.635.634.733.732.932.031.130.329.528.728.027.226.534.836.835.834.833.933.032.231.330.529.728.928.127.426.734.937.036.035.034.133.232.331.530.729.929.128.327.626.835.037.236.235.234.333.432.531.730.830.029.228.527.727.034
续表B测区测区混凝土强度换算值fa(MPa)回弹测区平均碳化深度值dm(mm)代表0.00.51.01.52.02.53.03.54.04.55.05.5值R6.035.137.436.435.434.533.632.731.831.030.229.428.627.927.135.237.636.635.634.733.832.932.031.230.329.528.828.027.335.337.836.835.834.934.033.132.231.330.529.728.928.227.435.438.037.036.035.134.133.232.431.530.729.929.128.327.635.538.237.236.235.334.333.432.531.730.830.029.228.527.735.638.437.436.435.434.533.632.731.931.030.229.428.627.935.738.637.636.635.634.733.832.932.031.230.429.628.828.035.838.837.836.835.834.934.033.132.231.430.529.728.928.235.939.038.037.036.035.134.133.232.431.530.729.929.128.336.039.238.237.236.235.334.333.432.531.730.930.029.228.536.139.438.437.436.435.534.533.632.731.931.030.229.428.636.239.738.637.636.635.634.733.832.932.031.230.429.628.836.339.938.837.836.835.834.934.033.132.231.430.529.728.936.440.139.038.037.036.035.134.133.232.431.530.729.929.136.540.339.238.237.236.235.334.333.432.531.730.830.029.236.640.539.438.437.436.435.434.533.632.731.931.030.229.436.740.739.638.637.636.635.634.733.832.932.031.230.429.636.840.939.938.837.836.835.834.934.033.132.231.330.529.736.941.140.139.038.037.036.035.134.133.232.431.530.729.937.041.440.339.238.237.236.235.234.333.432.531.730.830.035
续表B测区测区混凝土强度换算值fa(MPa)回弹测区平均碳化深度值dm(mm)代表0.00.51.01.52.02.53.03.54.04.55.05.5值R6.037.141.640.539.438.437.436.435.434.533.632.731.831.030.237.241.840.739.638.637.636.635.634.733.832.932.031.230.337.342.040.939.838.837.836.835.834.833.933.032.231.330.537.442.241.140.039.037.936.936.035.034.133.232.331.530.637.542.441.340.239.238.137.136.235.234.333.432.531.630.837.642.741.540.439.438.337.336.335.434.533.532.731.831.037.742.941.840.739.638.537.536.535.634.633.732.832.031.137.843.142.040.939.838.737.736.735.834.833.933.032.131.337.943.342.241.140.038.937.936.935.935.034.133.232.331.438.043.542.441.340.239.138.137.136.135.234.233.332.531.638.143.842.641.540.439.338.337.336.335.334.433.532.631.838.244.042.841.740.639.538.537.536.535.534.633.732.831.938.344.243.041.940.839.738.737.736.735.734.833.833.032.138.444.443.342.141.039.938.937.836.935.934.934.033.132.238.544.743.542.341.240.139.138.037.036.135.134.233.332.438.644.943.742.541.440.339.338.237.236.235.334.433.532.638.745.143.942.841.640.539.538.437.436.435.534.533.632.738.845.344.143.041.840.739.738.637.636.635.634.733.832.938.945.544.343.242.040.939.938.837.836.835.834.934.033.139.045.844.643.442.241.140.139.038.037.036.035.034.133.236
续表B测区测区混凝土强度换算值fa(MPa)回弹测区平均碳化深度值dm(mm)代表0.00.51.01.52.02.53.03.54.04.55.05.5值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
续表B测区测区混凝土强度换算值fa(MPa)回弹测区平均碳化深度值dm(mm)代表0.00.51.01.52.02.53.03.54.04.55.05.5值R6.041.150.649.348.046.745.544.343.142.040.939.838.837.736.841.250.949.548.247.045.744.543.342.241.140.038.937.936.941.351.149.848.547.245.944.743.542.441.340.239.138.137.141.451.450.048.747.446.144.943.742.641.540.439.338.337.341.551.650.248.947.646.445.144.042.841.740.639.538.537.441.651.850.549.147.846.645.444.243.041.940.839.738.637.641.752.150.749.448.146.845.644.443.242.140.939.938.837.841.852.350.949.648.347.045.844.643.442.241.140.039.038.041.952.651.249.848.547.246.044.843.642.441.340.239.238.142.052.851.450.048.747.446.245.043.842.641.540.439.438.342.153.051.650.349.047.746.445.244.042.841.740.639.538.542.253.351.950.549.247.946.645.444.243.041.940.839.738.742.353.552.150.749.448.146.845.644.443.242.141.039.938.842.453.852.351.049.648.347.045.844.643.442.341.240.139.042.554.052.651.249.948.547.346.044.843.642.541.340.339.242.654.352.851.450.148.847.546.245.043.842.741.540.439.442.754.553.151.750.349.047.746.445.244.042.941.740.639.642.854.753.351.950.549.247.946.645.444.243.041.940.839.742.955.053.552.150.849.448.146.845.644.443.242.141.039.943.055.253.852.451.049.648.347.145.844.643.442.341.240.138
续表B测区测区混凝土强度换算值fa(MPa)回弹测区平均碳化深度值dm(mm)代表0.00.51.01.52.02.53.03.54.04.55.05.5值R6.043.155.554.052.651.249.948.647.346.044.843.642.541.440.343.255.754.352.851.450.148.847.546.245.043.842.741.540.543.356.054.553.151.750.349.047.746.445.244.042.941.740.643.456.254.853.351.950.549.247.946.645.444.243.141.940.843.556.555.053.552.150.849.448.146.945.644.443.242.141.043.656.755.253.852.451.049.648.347.145.844.643.442.341.243.757.055.554.052.651.249.948.547.346.044.843.642.541.443.857.255.754.352.851.450.148.847.546.245.043.842.741.543.957.556.054.553.151.750.349.047.746.445.244.042.941.744.057.756.254.753.351.950.549.247.946.645.444.243.041.944.158.056.555.053.552.150.749.448.146.845.644.443.242.144.258.256.755.253.852.351.049.648.347.045.844.643.442.344.358.557.055.554.052.651.249.848.547.246.044.843.642.544.458.857.255.754.252.851.450.148.747.546.245.043.842.644.559.057.555.954.553.051.650.348.947.746.445.244.042.844.659.357.756.254.753.351.950.549.247.946.645.444.243.044.759.558.056.454.953.552.150.749.448.146.845.644.443.244.859.858.256.755.253.752.350.949.648.347.045.844.643.444.958.556.955.454.052.551.149.848.547.246.044.843.645.058.757.255.654.252.851.450.048.747.446.244.943.839
续表B测区测区混凝土强度换算值fa(MPa)回弹测区平均碳化深度值dm(mm)代表0.00.51.01.52.02.53.03.54.04.55.05.5值R6.045.159.057.455.954.453.051.650.248.947.646.445.143.945.259.257.656.154.653.251.850.449.147.846.645.344.145.359.557.956.454.953.452.050.749.348.046.845.544.345.459.758.156.655.153.752.250.949.548.247.045.744.545.558.456.855.353.952.551.149.748.447.245.944.745.658.657.155.654.152.751.349.948.647.446.144.945.758.957.355.854.352.951.550.248.847.646.345.145.859.157.656.154.653.151.750.449.047.846.545.345.959.457.856.354.853.452.050.649.348.046.745.546.059.658.156.555.053.652.250.849.548.246.945.646.159.958.356.855.353.852.451.049.748.447.145.846.258.557.055.554.052.651.249.948.647.346.046.3一58.857.255.754.352.851.450.148.847.546.246.459.057.556.054.553.051.750.349.047.746.446.559.357.756.254.753.351.950.549.247.946.646.659.558.056.454.953.552.150.749.448.146.846.759.858.256.755.253.752.350.949.648.347.046.858.456.955.453.952.551.149.848.547.246.958.757.155.654.252.751.350.048.747.447.058.957.455.854.452.951.550.248.947.640
续表B测区测区混凝土强度换算值fa,(MPa)回弹测区平均碳化深度值dm(mm)代表0.00.51.01.52.02.53.03.54.04.55.05.5值R6.047.159.257.656.154.653.251.850.449.147.847.2一59.457.856.354.853.452.050.649.348.047.359.658.156.555.053.652.250.849.548.247.459.958.356.855.353.852.451.049.748.447.558.557.055.554.052.651.249.948.647.658.857.255.754.352.851.450.148.847.759.057.555.954.553.051.650.349.047.859.357.756.254.753.351.850.549.247.959.557.956.454.953.552.150.749.348.059.758.256.655.153.752.350.949.548.158.456.955.453.952.551.149.748.258.657.155.654.152.751.349.948.358.957.355.854.352.951.550.148.459.157.556.054.553.151.750.348.559.357.856.254.853.351.950.548.659.658.056.555.053.552.150.748.759.858.256.755.253.752.350.948.858.556.955.454.052.551.148.958.757.155.654.252.751.449.058.957.455.954.452.951.641
续表B测区测区混凝土强度换算值fa(MPa)回弹测区平均碳化深度值dm(mm)代表0.00.51.01.52.02.53.03.54.04.55.05.5值R6.049.159.257.656.154.653.251.849.2一一一59.457.856.354.853.452.049.3一59.658.056.555.053.652.249.459.858.356.755.253.852.449.5一58.557.055.554.052.649.6一58.757.255.754.252.849.759.057.455.954.453.049.859.257.656.154.653.249.959.457.856.354.853.450.059.658.156.555.053.650.1一59.958.356.855.353.850.258.557.055.554.050.358.757.255.754.250.459.057.455.954.450.559.257.656.154.650.659.457.956.354.850.759.658.156.555.150.859.958.356.855.350.958.557.055.551.058.757.255.742
续表B测区测区混凝土强度换算值feu(MPa)回弹测区平均碳化深度值dm(mm)代表0.00.51.01.52.02.53.03.54.04.55.05.5≥6.0值R51.159.057.455.951.259.257.656.151.359.457.856.351.459.658.156.551.559.858.356.751.658.556.951.758.757.251.858.957.451.959.157.652.059.457.852.159.658.052.259.858.2 52.358.452.458.752.558.952.659.152.759.352.859.552.959.753.0注:表中未注明(即“一”的测区混凝土强度换算值为:15.0MPa或≥60.0MPa。43
附录C非水平方向检测时的回弹值修正值
表C非水平方向检测时的回弹值修正值
附录D回弹法检测泵送混凝土抗压强度报告D.0.1《回弹法检测泵送混凝土抗压强度报告》的编写格式见表D.0.1。表D.0.1[回弹法检测泵送混凝土抗压强度报告委托单位:报告编号:工程名称:龄期(d):构件部位:检测依据:设计强度:检测仪器:仪器编号:检测日期:报告日期:构件名称测区计算数据(MPa)轴线编号平均值标准差最小值推定值批量推定混凝土抗压强度检测构件测区最小值平均值标准差抗压强度推数数(MPa)(MPa)(MPa)定值(MPa)备注:批准:审核:校核:检测:46
D.0.2《回弹法检测泵送混凝土抗压强度报告》的原始记录编写格式见表D.0.2。表D.0.2回弹法检测泵送混凝土抗压强度原始记录委托单位:记录编号:工程名称:环境温度:构件编号:检测日期:检测仪器:仪器编号:碳化深度读数(mm)测区编号回弹值碳化深度平1#2#3#均值(mm)测区1测区 2测区 3测区10.)()(()()(2率定试验()()(()()()备注碳化深度测量仪编号:(钢砧编号:(温度计编号:()测试:记录:校核:47
1为便于在执行本标准条文时区别对待,对要求严格 程度不同的用词说明如下: 1)表示很严格,非这样做不可的: 正面词采用“必须”,反面词采用“严禁”; 2)表示严格,在正常情况下均应该这样做的: 正面词采用“应”,反面词采用“不应”或“不得” 3)表示充许稍有选择,在条件许可时首先应这样做的 止面词采用“宜”,反面词采用“不宜”; 4)表示有选择,在一定条件下可以这样做的用词,采用 “可”。 2条文中指明应按其他有关标准执行的写法为:“应 按...执行”或“应符合...要求或规定”
1为便于在执行本标准条文时区别对待,对要求严格 程度不同的用词说明如下: 1)表示很严格,非这样做不可的: 正面词采用“必须”,反面词采用“严禁”; 2)表示严格,在正常情况下均应该这样做的: 正面词采用“应”,反面词采用“不应”或“不得” 3)表示充许稍有选择,在条件许可时首先应这样做的 止面词采用“宜”,反面词采用“不宜”; 4)表示有选择,在一定条件下可以这样做的用词,采用 “可”。 2条文中指明应按其他有关标准执行的写法为:“应 按执行”或“应符合要求或规定”
7 《建筑结构检测技术标准》GB/T50344 2 《回弹仪》GB/T9138 3 《回弹法检测混凝土抗压强度技术规程》JGJ/T23 4 《钻芯法检测混凝土强度技术规程》JGJ/T384 5 国家计量检定规程《回弹仪》JJG817 6 《超声回弹综合法检测混凝土抗压强度技术规程》 T/CECS02
回弹法检测泵送混凝土抗压强度
现行行业技术规程、先进技术标准,开以多种方式 泛征求了有关单位和专家的意见,对主要问题进 行了反复讨论、协调和修改。本规程的编制为回弹 法检测广东地区按泵送施工要求配制混凝土的抗压 强度在实际工程中的推厂应用提供了技术依据。 为便于厂大检测、鉴定、设计、施工、科研、 学校等单位有关人员在使用本规程时能正确理解和 执行条文规定,编制组按章、节、条顺序编制了本 规程的条文说明,对条文规定的目的、依据以及执 仃中需注意的有关事项进行了说明。但是,本条文 说明不具备与标准正文同等的法律效力,仅供使用 者作为理解和把握规程规定的参考
目次1 总则54回弹仪3593.1技术要求593.2检定和率定.613.3保养.634检测技术.664.1般规定.664.2回弹值测量与计算,.704.3碳化深度值测量.715测强曲线746混凝土强度的推定.7853
1.0.1统一标称能量为2.207J的M225型回弹仪检 测方法,保证回弹法检测广东地区按照泵送施工要 求配制的混凝土抗压强度结果的可靠性是本规程制 定的目的。
1.0.2由于回弹法是通过回弹仪检测混凝土表面硬
度从而推算出混凝土强度的方法,因此,不适用于 表层与内部质量有明显差异或内部存在缺陷的混凝 土构件的检测。 本规程所述的混凝土材料是符合现行国家有关 标准的、由广东地区商品混凝土生产企业制作的混 疑土,未对采用如离心法、真空法、压浆法、喷射 法等特种成型工艺制作的混凝土开展试验研究;构 件生产中,有的并非一般机械成型工艺可以完成, 列如混凝土轨枕,上、下水管道等,就需采用加压 振动或离心法成型工艺,超出了本规程测强曲线的
适用范围。 国内、外试验研究表明,普通混凝土所用细骨料 的品种和粒径只要符合《普通混凝土用砂、石质量 及检验方法标准》JGJ52的规定,对回弹法测强没 有显著影响。对于再生混凝土、高性能混凝土,使 用本规程检测前应进行验证。 混凝土表面湿度对回弹法测强影响很大,应等待 混凝土表面十燥后再进行检测。粗骨料最大公称粒 径大于31.5mm时,已超出制本规程测强曲线时 听用混凝土粗骨料的最大粒径;泵送混凝土粗骨料 最大公称粒径大于31.5mm时已不能满足泵送的要 求。对于在非平面的构件上测得的回弹值与在平面 上测得的回弹值关系,国内目前尚无试验资料,现 参照国外资料,规定凡测试部位的曲率半径小于 250mm的构件一律不能采用本规程测强曲线。 可弹法的测试结果与混凝土的设计强度等级没 有直接关系,但实际工程中一般需将回弹法检测结 果与设计强度等级进行比较。本规程结合测强曲线
的区间范围(混凝土抗压强度≥15.0MPa且< 50.0MPa)及实际需要,给出适用范围的混凝土强度 等级为 C15~C60 本规程对强度等级为C15~C60混凝土进行抗 压强度检测,在实际工程应用中,对于临界条件下 不同回弹仪的选择,给出以下建议: 混凝土设计强度等级小于C60,且现场预留混 疑土试块抗压强度代表值低于60.0MPa时,建议采 用本规程M225型回弹仪进行检测: 如现场没有预留混凝土试块,或者混凝土试块 抗压强度代表值没有代表性,混凝土实际强度在 60.0MPa左右时,建议采用M225型回弹仪和H450 型回弹仪对部分构件分别进行预估检测,根据预估 检测结果选择回弹仪: 1当两种回弹仪的检测结果都小于60.0MPa 时,采用M225型回弹仪; 2当两种回弹仪的检测结果都不小于 60.0MPa时,采用H450 型回弹仪;
3当两种回弹仪的检测结果不一致时,采用其 也有效法(如:钻心法等)进行检测。 1.0.3通常情况下,混凝土强度的验收和评定应按 现行国家标准《混凝土结构工程施工及验收规范》 GB50204及《混凝土强度检验评定标准》GB/T5010 的规定,采用标准养护试件的抗压强度来检验混凝 土的强度质量,不允许用本规程的方法取代国家标 准对制作混凝士标准养护试件的要求。因此,按本 规程检测所推定的混凝士抗压强度,不能等同于施 L现场取样成型并标准养护28d或设计规定龄期所 得的混凝土试件抗压强度。但是,混凝土试件强度 评定不合格时,可按本规程检测方法推定结构中的 混凝土强度,并可作为结构是否需要处理的依据; 对使用中的结构需要检测混凝土强度,或者在混凝 土工程施工过程中出现下列情况时,可按本规程检 测方法推定混凝土强度: 1同条件养护立方体试件的试验结果不能满足 设计要求;
2标准养护试件强度缺乏代表性或试件数量不 足; 3对混凝土标准养护试件强度的检验结果有怀 疑; 4由于管理不善、施工质量不良,导致试件与 结构中混凝土质量不一致: 5监控工程建设过程中的混凝土施工质量。 1.0.4凡本规程涉及的其他有关方面,例如钻芯取 样,高空、深坑作业时的安全技术和劳动保护等, 均应遵守相应的标准和规范
3.1.1随着光电子技术在回弹仪上的应用,国
3.1.2由于回弹仪为计量仪器,因此在明显的位置
上要标明名称、型号、制造厂名(或商标)、出厂编 号及生产日期。回弹仪属于量具,在使用之前,应 由有资质的计量机构进行检定,取得计量合格证书, 使检测精度得到保证。
度推定结果的准确性。回弹仪的标准状态是统一仪 器性能的基础,是使回弹法广泛应用于现场的关键 所在;只有采用质量统一,性能一致的回弹仪,才 能保证测试结果的可靠性,并能在同一水平上进行 比较。标称能量为2.207J回弹仪的标准状态指标: 水平弹击时,弹击锤脱钩的瞬间,回弹仪的标准 能量E,即回弹仪弹击拉簧恢复原始状态所作的功 为:
E ==KL? × 784.532 × 0.075² = 2.207j 2
式中K一一弹击拉簧的刚度(N/m); L一一弹击拉簧工作时拉伸长度(m)。 标称能量为2.207J回弹仪的率定所用钢砧质量 为16.0kg。检验回弹仪的率定值是否符合80土2的 作用是:检验回弹仪的标准能量是否为2.207J:回 弹仪的测试性能是否稳定;机芯的滑动部分是否有 污垢等。 当钢砧率定值超出802范围时,不允许用混
疑土立方体试块上的回弹值予以修止,更不允许旋 转尾盖调零螺丝人为地使其达到率定值。此时,可 按本规程第3.3节要求进行常规保养,若保养仍不 合格,可送检定单位检定。 现有绝大多数数字式回弹仪都是在传统机械构 告和标准技术参数的基础上实现回弹值的数字化采 样的,即现有数字式回弹仪所得到的回弹值采样系 统都是把回弹仪的指针示值实现数字化采样。也只 有这种形式的数字回弹仪才符合现行回弹法技术规 程的使用要求。保留人工直读示值系统能使数字回 弹仪的操作者在实际检测过程中随时核对数字回弹 义所显示的采样值是否与指针示值相同,及时发现 仪器采样系统的故障。因此,规定数字式回弹仪应 带有指针直读系统,这是保证数字式回弹仪的数字 显示与指针显示一致性的基本要求,
3.2.1本条指出,检定混凝土回弹仪的单位应为有 资质的计量机构,并按照现行国家计量检定规程《回 弹仪》JJG817进行。 新出厂的回弹仪,由于在生产过程中的质量控 制水平不同,而且贮存运输过程会对回弹仪产生 定影响,为保证回弹仪后用时处于标准状态,因此 新回弹仪在使用前必须检定。 现行国家计量检定规程《回弹仪》JJG817规定 回弹仪的检定期限为6个月,并未区分回弹仪的类 型。 回弹仪经常规保养后,钢砧率定值仍不符合要 求,表明回弹仪已偏离标准状态,应进行检定。经 保养后率定值不合格的回弹仪如果不送检定,需送 厂家检修处理。 更换主要零件或检修后,回弹仪的整体性能会 产生变化,应进行检定。 遭受重撞击或其它损害的回弹仪,无法采用 常规保养的方式使其处于标准状态,应进行检定。
3.2.2本条汇总整理了回弹仪需进行率定的要求。
为了保证在使用中及时发现和纠正回弹仪的非标准 状态,每个检测项目,或者每天在使用回弹仪进行 现场检测前后都要进行率定
3.2.3本条参照现行国家计量检定规程《回弹仪》
JG817给出了回弹仪的率定方法,完善了现行行业 标准关于率定的规定中给出的钢砧率定值的解读。 可弹仪四个方向的率定值,是指弹击杆分别在0 (初始状态)、90°(旋转1次)、180°(旋转2次) 270°(旋转3次)四个方向的率定值。
3.3.1本条主要规定了回弹仪常规保养的要求
规保养时,必须先使弹击锤脱钩后再取出机芯,否
则会使弹击杆突然伸出造成伤害。取机芯时要将指 针轴向上轻轻抽出,以免造成指针片折断。数字式 回弹仪结构和原理较复杂,其厂商已提供了使用和 维护手册,应按该手册的要求进行维护和保养。需 要注意的是,维护保养的人员必须是对回弹仪工作 原理很熟悉的,或经过相应技术培训的人员
3.3.3本条给出了回弹仪常规保养的特别注意事
项。各零部件清洗完后,不能在指针轴上抹油;否 则,使用中由于指针轴的污垢,将使指针摩擦力变 化,直接影响了检测结果。由于回弹仪的使用环境 中,粉尘含量较高,加之仪器内各相互移动的部件 间有相对磨损,因此需经常做好维护和保养工作。 3.3.4、3.3.5回弹仪每次使用完毕后,应及时清除 表面污垢。不用时,应将弹击杆压入仪器内,必须 经弹击后方可按下按钮锁住机芯,如果未经弹击而 锁住机芯,将使弹击拉簧在不工作时仍处于受拉状 态,极易因疲劳而损环。存放时回弹仪应平放在于 燥阴凉处,如存放地点潮湿将会使仪器锈蚀。数字
项。各零部件清洗完后,不能在指针轴上抹油;否 则,使用中由于指针轴的污垢,将使指针摩擦力变 化,直接影响了检测结果。由于回弹仪的使用环境 中,粉尘含量较高,加之仪器内各相互移动的部件 间有相对磨损,因此需经常做好维护和保养工作
表面污垢。不用时,应将弹击杆压入仪器内,必须 经弹击后方可按下按钮锁住机芯,如果未经弹击而 锁住机芯,将使弹击拉簧在不工作时仍处于受拉状 态,极易因疲劳而损环。存放时回弹仪应平放在十 燥阴凉处,如存放地点潮湿将会使仪器锈蚀。数字
可弹仪内的电池长期不用,电池内的电解质易发生 泄漏,腐蚀电路的连线系统,应取出电池。
4.1.1若不进行专门的技术培训,则会对同一构件
混凝土强度的检测结果存在因人而异的混乱现象 本条规定凡丛事本项检测的人员应经过专业培训
4.1.2本条列举的 1~6 项资料,是为了对被检
构件有全面、系统的了解。此处,必须了解水泥的 安定性,如水泥安定性不合格则不能检测,如不能 确切了解水泥安定性合格与否应在检测报告上说 明,以免产生由于后期混凝土强度因水泥安定性不 合格而降低或丧失所引起事故责任不清的问题。另 外,了解清楚混凝土浇筑日期是为了推算检测时构 件混凝土的龄期,了解混凝土施工工艺等是为了确 认混凝土适用本规程检测,也可为分析处理构件混 凝土强度时提供参考。
4.1.3按单个构件或按批抽样进行检测,是采用回
4.1.3按单个构件或按批抽样进行检测,是采用回 弹法对混凝土结构进行强度推定的两种常见形式。
弹法对混凝土结构进行强度推定的两种常见形工
4.1.4对于单个受检构件,
个;将某一方向尺寸不大于4.5m且另一方向尺寸 不大于0.3m,作为是否需要10个测区数的界线
4.1.5本规程的测强曲线是通过对混凝土试件进行
水平方向测试浇筑侧面建立的。受检构件布置测区 时,相令部两测区的间距及测区离构件端部或施工缝 的距离应遵守本条规定。 回弹法的“测区”是指每一试样的测试区域 每一测区相当于该试样的同条件混凝土试块。建立 测强曲线时是在每个试块的相对浇筑侧面进行回弹 测试,因此实际在测区布置时,宜选在构件两个对 称的可测面上,当可测面的对称面无法检测时,也 可在一个检测面上布置测区。 测区面积不宜大于0.04m²,尺寸宜为200mm× 200mm;受构件尺寸限制,测区可调整采用不同边 长。
检测面应为混凝土原浆面,已经粉刷的构件应 将粉刷层清除干净。注意,切不可误将砂浆粉刷层 当作混凝土原浆面进行检测。如果养护不当,混凝 土表面会产生疏松层,无其在气候十燥地区更应注 意,应将疏松层清除后方可检测,否则会造成误判。 在记录纸上描述测区在构件上的位置和外观质 量(例如:有无裂缝),自的是以备推定和分析处理 构件混凝土强度时参考。
4.1.6当按批抽样检测时,四个条件同时满足,方 可视为同批构件。
在短期内进行较多数量的检测,以取得代表性较高 的总体混凝土强度数据,故规定:按批抽样检测的 构件,抽样数量不得少于同批构件总数的30%且不 得少于10个。当同批构件数量过多时,抽样数量可 按照现行国家标准《建筑结构检测技术标准》GB/T 50344进行适当调整 此外,抽取试样应严格遵守“随机”的原则,
并宜由建设单位、监理单位、施工单位会同检测单 位共同商定抽样的范围、数量和方法。
5.0.2条规定的混凝土原材料和龄期有较大差异时, 或者对回弹检测结果有怀疑时,应采用同条件养护 立方体试件或在测区钻取混凝土芯样试件进行修 正。修正时,同条件养护立方体试件边长应为 150mm,试件数量应不少于6个;芯样数量应符合 现行行业标准《钻芯法检测混凝土强度技术规程》 IGJ/T384的规定。当同批构件数量较多时,可豹情 增加修止所用的立方体试件数或芯样试件数。 这里需要注意的是:每一个钻取芯样的部位均 应在回弹测区内,先测定测区回弹值、碳化深度值 然后再钻取芯样。1个混凝土芯样只能制作1个芯 样试件进行抗压试验,不可以将较长芯样沿长度方 向截取为几个芯样试件来计算修正量。混凝土芯样 直径宜为100mm,高径比为1。芯样的钻取、加工 计算可参照现行行业标准《钻芯法检测混凝土强度
技术规程》JGJ/T384的规定进行。 考虑到芯样强度计算时,不同的规格修正会带 来新的误差,因此优先选用直径为100mm的混凝 芯样,在工程实际中经常会出现构件中钢筋较密或 钻孔孔径对构件工作性能有较大影响等不满足直径 为100mm芯样的取样条件,便只能考虑小直径芯样 试件,但其直径不应小于70mm。
4.2.1、4.2.2规定每一测区读取记录16点回弹值, 它不包含弹击隐藏在薄薄一层水泥浆下的气孔或石 子上的数值,这两种数值与该测区的止常回弹值偏 差很大,很好判断。同一测点只允许弹击一次,若 重复弹击则后者回弹值高于前者,这是因为经弹击 后该局部位置较密实,再弹击时吸收的能量较小从 而使回弹值偏高。 检测时应注意回弹仪的轴线要始终垂直于混凝
土检测面,并且缓慢均匀施压不能冲击,不宜用力 过猛,否则回弹值读数不准确。 一个回弹测点测试完毕,可将回弹仪的弹击杆 玉在混凝土表面的测点上,准确读取该测点回弹值: 也可按下回弹仪上的按钮,锁住机芯再读取该测点 回弹值。 读数完毕后,应快速复位,使回弹仪的弹击杆 自机壳内伸出,挂钩挂上弹击锤,待测试下一个回 弹测点。 对于薄壁小型构件,如果约束力不够,回弹时 产生颤动,会造成回弹能量损失,使检测结果偏低。 因此必须加以可靠支撑,使之有足够的约束力方可 检测。
4.2.3本条规定的测区回弹代表值计算方法和建立
4. 3碳化深度值测量
4.3.1本规程附录B中测区混凝土强度换算值由回
4.3.1本规程附录B中测区混凝土强度换算值由回 弹值及碳化深度值两个因素确定,因此需要具体确 定每一个测区的碳化深度值。当出现测区间碳化深 度值极差大于2.0mm情况时,可能预示该构件混凝 土强度不均匀,因此要求每一测区应分别测量碳化 深度值。
4.3.2由于现在所用水泥掺合料品种繁多,有些水
泥水化后不能立即呈现碳化与未碳化的界线,需等 待一段时间显现。因此本条规定了量测碳化深度时 需待碳化与未碳化界线清楚时再进行量测的内容。 与回弹值一样,碳化深度值的测量准确与否,直接 影响推定混凝土强度的准确性,因此在测量碳化深 度值时应为垂直距离,并非孔洞中显现的非垂直距 离。测量碳化深度值时应采用专用碳化深度测量仪 每个点在不同方位测量3次,每次测量碳化深度精 确到0.25mm,3次测量结果取平均值,精确到 0.5mm。当测区的碳化深度的极差大于2.0mm时, 可能预示着该构件的混凝土强度不均匀,因此要求
每一个测区均需要测量碳化深度值。对于因养护不 当及酸性隔离剂等因素引起的异常碳化,可用其他 方法对检测结果进行修正。
5.0.1测强曲线为经验公式,根据制定曲线时所用 混凝土立方体试件的条件范围,对本规程测强曲线 适用范围做了具体规定,不得超范围直接使用。对 于部分适用条件(如:测试龄期等)差异较大时, 可采用同条件养护立方体试件或在测区钻取混凝土 芯样试件进行修正,但不得延长曲线外推或者扩大 适用范围
州、中山、东莞、珠海、深圳、清远、佛山等地, 依据有关泵送混凝土原材料的现行国家标准和行业 标准来选取原材料,采用参编单位所在地工程常用 泵送混凝土建筑材料为试验原材料,包括水泥、粗 骨料、细骨料、矿物掺合料、外加剂、水等,根据 各地用于实际工程配合比原则设计配合比,生产各 强度等级泵送混凝土试块,并记录原材料的产地
品种、规格,泵送混凝土拌合物落度,混凝土配 合比及每立方米材料用量等。 本测强曲线试验使用的粗骨料为花岗岩、石灰 岩等,细骨料为河砂、水洗砂等,水泥为硅酸盐水 泥、普通硅酸盐水泥等,矿物掺合料为粉煤灰、矿 粉、微珠粉等,外加剂为聚羧酸系减水剂、萘系减 水剂等。因此在试验时所包括的内容(如:水泥、 粗骨料、细骨料、矿物掺合料、外加剂、水等原材 料,测试龄期、试件强度等级等)均应作为本地区 则强曲线的适用范围。 对广东省内有代表性地区提供的5000多组试 验数据,按照最小二乘法的原理,通过回归分析后 得到的地区测强曲线公式为本规程第6.0.1条中式 (6.0.1)。通过省内分别来自广州、佛山、东莞、深 圳、中山、珠海、江门、湛江、潮州、韶关等共10 个地区500多组实际工程检测数据对该测强曲线的 验证,结果与测强曲线的符合性好,表明该测强曲 线科学可靠。该公式经验证符合地区测强曲线的误
差要求,具体参数指标如表1所示:
表1测强曲线公式(6.0.1)参数指标
该测强曲线公式与全国部分地方测强曲线公式 相比,在混凝土抗压强度区间(15.0~60.0MPa范围 内,各地的测强曲线中回弹值既有一定的差异,同 时又比较接近,这就充分说明了本规程制定的泵送 混凝士的测强曲线的可靠性。 下表2是全国部分地方测强曲线公式的回弹值 和强度值区间:
表2全国部分地方测强曲线公式回弹和强度区间
6.0.1构件的每一测区的混凝土强度换算值,是由 母一测区的回弹代表值和碳化深度值查表得出。 实际工程中短龄期混凝土可能存在假性碳化, 对检测结果有显著影响。当对短龄期混凝土碳化深 度值有怀疑时,建议对回弹检测结果进行钻芯修止 或直接采用钻芯法检测混凝土强度。
DBJ46-041-2019标准下载6.0.2现行行业标准《钻芯法检测混凝土强度技术
6.0.3此条给出了测区混凝土强度换算值的平均值 及标准差的计算方法。需要说明的是,在计算标准 差时,强度平均值应精确至0.01MPa,否则会因二 次数据修约而增大计算误差。注意按批抽样进行混
凝土强度检测时,其测区混凝土强度换算值的平均 直和标准差,应采用该同批构件所有抽检构件的测 ×混凝土强度换算值来进行计算。 6.0.4当测区数量不少于10个时,为了保证构件的 混凝强度满足95%的保证率,采用数理统计的公 式计算强度推定值;当构件测区数少于10个时,因 样本太少,取最小值作为强度推定值。 若测区混凝土强度换算值<15.0MPa或 >60.0MPa,因超出了本规程强度换算方法的规定适 用范围,故该测区的混凝强度换算值应表述为“< 15.0MPa”,或“≥60.0MPa”。若构件测区中有<15.0 MPa的测区,因不能计算构件混凝土的强度标准差, 则该构件混凝土强度的推定值应表述为“<15.0 MPa”;若构件测区中有≥60.0MPa的测区,也不能 汗算构件混凝土的强度标准差,此时,构件混凝土 强度的推定值取该构件各测区中最小的测区混凝士 强度换算值。
6.0.5、6.0.6按批抽样检测混凝强度时,如果测
6.0.5、6.0.6按批抽样检测混凝土强度时QX/T 542-2020 中小河流洪水和山洪致灾阈值雨量等级,如果测
区混凝土强度换算值的标准差过大,说明该同批构 件的混凝土质量不均匀,因此不能按批进行强度推 定,应全部按单个构件进行强度推定。 6.0.7检测报告是工程测试的最后结果,是混凝土 结构是否需要处理的依据,宜按统一格式出具。